Cast Resin Dry-Type Transformers (SCB Series)

Home  /  Products  /  Cast Resin Dry-Type Transformers
SCB10 • SCB14 • SCB18 • Traction Rectifier

Cast Resin Dry-Type Power Transformers

Flame-retardant, self-extinguishing vacuum cast epoxy resin insulation with micro-void free partial discharge < 5pC. Designed for high fire-safety environments, commercial high-rises, urban transit systems, and hyperscale data centers.

Cast Resin Dry-Type Transformer
SCB Series Epoxy Cast Resin Dry Transformer (IP20 Enclosure Available)
// Safety & Durability

Maximum Fire Safety & High Short-Circuit Mechanical Strength

AIKey SCB dry-type transformers encapsulate high-voltage coils with imported epoxy resin and glass fiber rovings in a multi-stage vacuum differential pressure casting autoclave. Once cured, the winding forms a solid cylinder with superior mechanical rigidity and flame retardancy.

  • ✓ Partial Discharge < 5pC: Controlled under strict vacuum degassing, far superior to the IEC standard requirement of ≤ 10pC, ensuring 30+ years of dielectric life.
  • ✓ Class F (155°C) / Class H (180°C) Insulation: High thermal endurance allows 120% continuous overload operation when equipped with cross-flow cooling fans.
  • ✓ Certified E2, C2, F1 Ratings: Moisture-proof (E2 condensation), thermal shock resistant down to -25°C cold start (C2), and self-extinguishing non-toxic emissions (F1).
  • ✓ Intelligent Thermal Protection: Embedded PT100 platinum thermal sensors in low-voltage windings connect to an RS-485 microcomputer controller with auto-fan and trip contacts.

10kV Class Cast Resin Dry-Type Distribution Transformers (SCB14 / SCB18 Series)

Rated Capacity (kVA) High Voltage (kV) Low Voltage (V) Connection Symbol SCB14 Po (W) SCB18 Po (W) Load Loss Pk 120°C (W) Impedance Uk (%)
5010, 10.5 ± 2×2.5%400 / 230Dyn112301901,0004.0
10010, 10.5 ± 2×2.5%400 / 230Dyn113703001,5704.0
16010, 10.5 ± 2×2.5%400 / 230Dyn115104202,1304.0
25010, 10.5 ± 2×2.5%400 / 230Dyn117105802,7604.0
40010, 10.5 ± 2×2.5%400 / 230Dyn119808003,9904.0
63010, 10.5 ± 2×2.5%400 / 230Dyn111,3401,1005,8804.0 / 6.0
80010, 10.5 ± 2×2.5%400 / 230Dyn111,5901,3006,9606.0
100010, 10.5 ± 2×2.5%400 / 230Dyn111,8701,5308,1306.0
125010, 10.5 ± 2×2.5%400 / 230Dyn112,2001,8009,6906.0
160010, 10.5 ± 2×2.5%400 / 230Dyn112,6502,17011,7306.0
200010, 10.5 ± 2×2.5%400 / 230Dyn113,2202,64014,4506.0 / 8.0
250010, 10.5 ± 2×2.5%400 / 230Dyn113,8003,11017,1708.0

* IP20, IP23, and IP33 protective enclosures with forced air cooling fans (AF) available. 20kV and 35kV dry-type transformers and 12/24-pulse traction rectifiers built to order.